Pathmaker Messages Manual
Pathmaker Messages
067870 Tandem Computers Incorporated 2–81
Illegal terminal for a Nowait request —
new-process
Cause. You tried to generate a requester or server from the project home terminal.
Issued by the Pathmaker product.
Effect. New process startup fails.
Recovery. You cannot generate a requester or server from this terminal because it is the
project's home terminal. Either change the home terminal for the project by using
PMPROJECT ALTER or generate the requester or server from another terminal.
Incomplete object source description generated —
object-name
Cause. During an OUTPUT statement, PMADL could not finish generating ADL
source code for an object. Typically, this condition is caused by a file system error on
one of the catalog files that describes the object.
Issued by PMADL.
Effect. PMADL generates syntactically invalid ADL source code for the object and
continues with the next object, if any.
Recovery. Correct the condition that caused the problem and retry the OUTPUT
statement.
Incorrect ALTFILE name in file:
file-name
Cause. The Pathmaker program encountered a bad value in one of the alternate keys in
this project catalog file.
Issued by the Pathmaker product.
Effect. Pathmaker startup fails.
Recovery. Note this error message and contact your Tandem representative.
Incorrect message to server
Cause. Internal error.
Issued by the Pathmaker product.
Effect. Operation fails.
Recovery. Contact support.