Pathway/iTS Management Programming Manual
TCP Error Messages
NonStop Pathway/iTS Management Programming Manual—426749-002
12-50
Error-Message Range 3000 Through 3999
For a description of tokens that are present in this event message but are not listed or 
described here, see “Event Management,” in Section 6 of the TS/MP Management 
Programming Manual. 
Token Descriptions
ZSPI-TKN-ERROR 
contains ZPWY-ERR-TCP-INSPECTATBKPT.
ZPWY-TKN-REQCOMMAND 
contains ZPWY-CMD-INSPECT.
ZPWY-TKN-REQOBJECTTYPE 
contains ZPWY-OBJ-TERM.
ZPWY-TKN-REQTERMNAME 
contains the name of the TERM object for which the Inspect command was issued.
Effect. The Inspect operation fails.
Recovery. Resubmit the Inspect command when the TERM object is not at a program 
breakpoint.
3224: ZPWY-ERR-TCP-INSPECTIO
A file-system error occurred when the TCP was unable to complete a request to IMON 
or to start an Inspect process.
This error does not appear in the RETCODE token or in an error list; it appears only in 
response to a STATUS TCP or STATUS TERM command.
Effect. The operation fails.
Recovery. For information regarding the specified file-system error, see the Guardian 
Procedure Errors and Messages Manual.
ZSPI-TKN-ERRLIST token-type ZSPI-TYP-LIST.
ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR.
ZPWY-TKN-REQCOMMAND token-type ZSPI-TYP-INT.
ZPWY-TKN-REQOBJECTTYPE token-type ZSPI-TYP-UINT.
ZPWY-TKN-REQTERMNAME token-type ZPWY-TYP-TERMNAME
ZPWY-TKN-ERRCOMMAND token-type ZSPI-TYP-INT.
ZPWY-TKN-ERROBJECTTYPE token-type ZSPI-TYP-UINT.
ZPWY-TKN-TERMNAME token-type ZSPI-TYP-TERMNAME.
ZSPI-TKN-ENDLIST token-type ZSPI-TYP-SSCTL.