Pathway/iTS SCUP Reference Manual
Table Of Contents

SCUP Messages
HP NonStop Pathway/iTS SCUP Reference Manual—520269-002
A-14
Converter Messages
Effect. The conversion continues after generating the warning. The application will fail
at run time if the program units identified by the specified program-ids are not
converted.
Recovery. Include the missing program units in the current POBJ file and reconvert
the application.
Cause. The converter traces the call sequence in the POBJ file starting with the
INITPROG. The converter displays this message if it was unable to resolve a CALL
sequence because the call sequence was of the form CALL WS1, so that it could not
be resolved at the time of conversion. The displayed message identifies the
associated program IDs.
Effect. The conversion continues after generating the warning. The application will fail
at run time if the working-storage item represented by the identifier in the CALL
statement contains a program unit name that does not exist in the current POBJDIR
file.
Recovery. If a failure occurs at run time, convert the program unit identified in the
working-storage item referenced in the CALL statement. If no run-time failure occurs,
no recovery action is necessary.
Warning - Unable to resolve program units used in CALL working-storage
statement