Pathway/iTS System Management Manual (G06.24+)

TCP Messages (Numbers 3000-3999)
HP NonStop Pathway/iTS System Management Manual426748-002
13-43
TCP Messages
Supporting documentation such as Event Management Service (EMS) logs, trace
files, and dump files, if applicable
If your local operating procedures require contacting the GCSC, supply your system
number and the numbers and versions of all related products as well.
3202
Cause. The TCP encountered an unknown terminal identifier. This is an internal error.
Effect. The request cannot be processed.
Recovery. Contact your service provider and provide all relevant information as
follows:
Descriptions of the problem and accompanying symptoms
Details from the message(s) generated
Your PATHMON configuration file and PATHMON process version
A description of the application task that was in progress when the error was
encountered
Supporting documentation such as Event Management Service (EMS) logs, trace
files, and dump files, if applicable
If your local operating procedures require contacting the GCSC, supply your system
number and the numbers and versions of all related products as well.
3203
Cause. The TCP does not support the SCREEN COBOL function that was used.
Effect. The SCREEN COBOL program cannot be executed.
Recovery. Use a more recent version of the TCP.
3204
Cause. The TCP is not in the appropriate state for the attempted operation.
This error is often issued after a STOP TCP command is attempted when the terminals
are still running.
Effect. The operation fails.
*3202* TCP tcp-name, TERMINAL IDENTIFIER NOT KNOWN TO TCP
*3203* TCP tcp-name, FUNCTION UNIMPLEMENTED
*3204* TCP tcp-name, TCP STATE DOES NOT ALLOW OPERATION