Pathway/iTS System Management Manual (G06.24+)
HP NonStop Pathway/iTS System Management Manual—426748-002
C-1
C
Configuration Limits and Defaults
Table C-1 lists global limits for various items within each PATHMON environment.
Table C-2 on page C-2 lists each PATHCOM parameter that has a value range or limit,
its corresponding SPI token or field name, its value range, and its default value. This
table is organized alphabetically, by PATHCOM parameter. These limits and defaults
are subject to change with product SPRs or with new software releases.
SPI tokens and fields are used in the management programming interface to
PATHMON environments. For more information about this interface, see the TS/MP
Management Programming Manual.
Note. These limits are subject to change with product SPRs or with new software releases.
Table C-1. Global PATHMON Environment Limits
Item Limits Per PATHMON Environment
PROGRAM objects Maximum of 4095 supported by each PATHMON process; suggested
maximum of 4094 to avoid error 1108.
Maximum of 100 concurrent waited RUN PROGRAM requests from
PATHCOM processes and START PROG requests from SPI
processes; maximum of 4095 if using nowaited operations.
TCP objects Maximum of 15 different POBJ files per TCP.
Using the HP Inspect symbolic debugger: Each TCP can control a
maximum of 8 terminals simultaneously running the Inspect utility, and
can process a total of 20 program breakpoints for all SCREEN
COBOL programs under inspection.
Maximum concurrent links per TCP to the same server process is the
value of LINKDEPTH.
TERM objects Maximum of 4095 supported by each PATHMON process; suggested
maximum of 4094 to avoid error 1101.