Pathway/iTS System Management Manual (G06.24+)
Setting the DISPLAY-PAGES Parameter
HP NonStop Pathway/iTS System Management Manual—426748-002
F-2
Determining the DISPLAY-PAGES Value
Determining the DISPLAY-PAGES Value
The correct value of the DISPLAY-PAGES parameter depends on the application
being run. An inappropriate value for DISPLAY-PAGES can result in the following
consequences:
•
If the value of DISPLAY-PAGES is too large, there will not be enough room in the
terminal’s field-attribute area for all the field-attribute entries. This causes the
terminal to abort with the terminal error ALL FIELDS USED.
•
If the value of DISPLAY-PAGES is too small, the terminal’s RAM will not be used
to its full capacity. Consequently, performance is not as good as it could be
because the number of screens that could be recalled is not at its maximum.
The factors that determine the correct value for the DISPLAY-PAGES parameter are
the number of field-attribute entries per screen definition, and terminal capacity. The
information in the following paragraph helps you estimate the number of field-attribute
entries. The tables in the remainder of this section help you match terminal type to the
average number of field-attribute entries to determine the appropriate DISPLAY-
PAGES value. Using the appropriate DISPLAY-PAGES value allows a terminal to
achieve its highest performance level without exceeding its fixed amount of RAM.
Figure F-1. RAM Organization Within a Terminal
Screen A
Field-Attribute Entries Area: Screen A
Field-Attribute Entries Area: Screen B
Terminal Random Access Memory (RAM)
Screen-Image Area Field-Attribute Entries Area
Screen B
Screen C
Field-Attribute Entries Area: Screen C
VST024.vsd