PEEK Reference Manual

PEEK Syntax and Examples
PEEK Reference Manual — 529657-006
2 - 21
INTERRUPTS Option
CLEANQ: FULLS FRLST:HITS CLOCK:CALLS FAILS CYCLES ALIASES: FAILS
0 0 739234 753 0 1.02 0 0
INTERRUPTS Option
Use the INTERRUPTS option to display counters for interrupt process (IP) and auxillary
process (AP) events. For H-series RVUs and J-series RVUs, interrupt handlers are
replaced by interrupt processes. Interrupt handlers have one or more corresponding
interrupt process. Some interrupt handlers are combined into a single-process general
fault handler (GFH), which handles several kinds of events such as traps, process
timer timeouts, and pending ownership events. Dispatcher is the only interrupt handler
that does not have a corresponding interrupt process.
When you enter PEEK INTERRUPTS, an output similar to this example is generated:
> PEEK INTERRUPTS
PEEK - T9050G09 - (05AUG02) SYSTEM \VIOLET
COPYRIGHT TANDEM COMPUTERS INCORPORATED 1981, 1985, 1988, 1990
SYSTEM \VIOLET
22 FEB 2004 , 13:48__ELAPSD 161:38:32__CPU 2(NSR-T)
INTRPTS: DISP BUS HIIO IIO TIME FAULT
41,180,423 46,599,852 0 0 3,982,934 2,284,217
SCHANL CME UCME MAB BKPT OSP PFAIL PON
0 0 0 3 5,589 0 0 0
IFAIL STKOV ARITHOV SAMPLE
100 1 11 0
Note. For a system running J06.06 or earlier J-series RVUs and H06.17 or earlier H-series
RVUs, NRL is displayed as a four-line output with the small-index (S) and medium-index (M)
entries for NRL and PPL on separate lines. This four-line output is compressed to a single line
NRL output from J06.07/H06.18 series onwards.
For a system running J06.14 and later J-series RVUs or H06.25 and later H-series RVUs, the
enhanced PME table, OSS SHM, and OSS SEM in
formation are included in the output.
For a system running J06.09 and later J-series RVUs or H06.20 and later H-series RVUs, the
FLEXPOOL64 info