  During the obeying of files, a STRTPVP error may be generated. This occurs due to the 
command to stop the processes may not result in the process(es) being stopped. The 
recovery is to “Skip Command”. 
  After a new install user might encounter an error ems message “CSVR:Could not open 
file WDSM001 Error 11”. CPROCAPP creates the WDSM001 file which CSVRAPP 
attempts to open. If due to timing issues, CSVRAPP tries to open this file before 
CPROCAPP has had a chance to create it, then this error message would occur. If this 
occurs after a fresh install, then it can be ignored. 
          [Back to TOC]
2-2-3 Manual Install (NonStop) 
In situations where the Wizard Install is not possible users also have an option to perform the 
installation manually. 
2-2-3-1 Overview 
For performing manual installation, the user will need to FTP files manually and follow the 
installation procedure described below. Note that this is not our recommended process of 
installation. 
2-2-3-2 Process 
For the Manual Installation, use the WS_SW\Manual Install\ascii and \binary folders from the 
CD as specified below: 
a.  The following files need to be transferred in ‘ASCII’ mode to $volume.subvolume 
COLLCONF 
INSTPVP 
PVPBAMIM 
PVPCONF 
STOPPVP 
STRTPVP 
b.  The following files need to be transferred in ‘BINARY‘ mode to $volume.subvolume 
CPROCAPP 
CSVRAPP 
FINFLIB 
FINFO 
FDIST 
LISTAPP 
POCKETVP 
PROCMAN 
PSVRAPP 
PVPEVTS 
PVPTMPAK 