Table 2 Status Messages and Corresponding Halt Codes (continued)
Millicode Halt NumberStatus Message
%100526POST has successfully completed
%002000Power fail, lost memory
%100010Priv instruction failed
%100232Reset after error freeze
%100213Spurious bus error
%177777Spurious interrupt
%100214TLB exception
%100230TLB exception failure
%100207Unexpected break
%000103Unexpected exception
%100210Unexpected interrupt
%100222Watch exception taken
Millicode Halt Codes
%000000 Interrupt before WCS load
Cause
The writable control store (WCS) was not loaded when an interrupt was present. This halt can
also occur after you try to dump a processor that has lost its millicode due to a power failure or
when the processor is being primed for a system-load operation or reload operation before a
memory dump.
Effect
The processor halts. The rest of the system is not affected.
Recovery
If this halt occurs when you are loading a processor, try reloading it. If the reload attempt is
unsuccessful, or the halt occurs during some other operation, see Processor Halt Monitoring and
Recovery (page 10). Before attempting a memory dump operation, contact your service provider
or the Global NonStop Solution Center (GNSC), as directed by your local operating procedures.
%000002 I/O device did not reply
Cause
The device with the system image did not respond.
Effect
The processor halts. The rest of the system is not affected.
Recovery
See Processor Halt Monitoring and Recovery (page 10). Before attempting a memory dump
operation, contact your service provider or the Global NonStop Solution Center (GNSC), as
directed by your local operating procedures.
%000004 I/O transfer timed out
Cause
A timeout occurred during a system-load operation and the transfer of the system image was
not completed.
Millicode Halt Codes 13