Processor Halt Codes Manual
Cause
The boot millicode’s PROM_CODE_DATE does not match between internal modules. This generally
indicates that the FIRMUP operation on the boot millicode was not successful.
Effect
The processor halts. The rest of the system is not affected.
Recovery
First perform a firmware update of the boot millicode by using the OSM or TSM facility. Then
perform a hard reset on the processor by using the OSM or TSM Low-Level Link.
%100532
Cause
The boot millicode was unable to get a data channel to download the SCSI boot code.
Effect
The processor halts. The rest of the system is not affected.
Recovery
See Processor Halt Monitoring and Recovery (page 10). After taking a memory dump of the
affected processor, replace the customer-replaceable unit (CRU), and contact your service provider
or the Global NonStop Solution Center (GNSC), as directed by your local operating procedures.
%100572
Cause
The boot millicode could not load all of its segments into memory.
Effect
The processor halts. The rest of the system is not affected.
Recovery
Perform a firmware update of the service processor (SP) code by using the OSM or TSM facility.
%100600
Cause
An unknown SCSI error occurred.
Effect
The processor load or tape dump fails; the processor remains halted. The rest of the system is
not affected.
Recovery
Check that you specified the correct slot location for the device you are attempting to access. If
attempting a tape dump, check that the tape is properly loaded, online, and write-enabled. Then
retry the operation. If the problem recurs, contact your service provider or the Global NonStop
Solution Center (GNSC), as directed by your local operating procedures.
%100601
Cause
The system-load operation is not one of the following: DISKBOOT, TAPEBOOT, or TAPEDUMP.
Effect
The system-load operation fails; processors remain halted.
Recovery
Check that you specified the correct slot location for the device you are attempting to access. If
attempting a tape dump, check that the tape is properly loaded, online, and write-enabled. Then
46 Millicode Halt Code Descriptions