Processor Halt Codes Manual

Effect
None.
Recovery
Informational message only; no corrective action is needed.
%177777 Spurious interrupt
Cause
A spurious interrupt occurred. This halt might indicate that the processor is already halted or
that the system image has not been loaded into the processor.
Effect
The processor halts; the processor remains halted. The rest of the system is not affected.
Recovery
See Processor Halt Monitoring and Recovery (page 10). Before attempting a memory dump
operation, contact your service provider or the Global NonStop Solution Center (GNSC), as
directed by your local operating procedures.
H-Series and J-Series Codes
Many of the previous halt codes were common to both G and H-series RVUs, but the following
section documents the cause, effect, and recovery for millicode halt codes specific to H- and J-series
RVUs.
%100003 MICROHALT_HARDWARE_FAILED
Cause
The boot code detected a hardware error during the boot process.
Effect
The processor halts. The rest of the system is not affected.
Recovery
See Processor Halt Monitoring and Recovery (page 10). Take a memory dump and contact your
service provider or the Global NonStop Solution Center (GNSC), as directed by your local
operating procedures.
%100205 MICROHALT_SOFT_RESET
Cause
An internal reset was performed due to Mini-Reintegration.
Effect
The processor halts. The rest of the system is not affected.
Recovery
Load the processor. If the operation is unsuccessful, contact your service provider or the Global
NonStop Solution Center (GNSC), as directed by your local operating procedures.
%100730 MICROHALT_BOOT_AVT_MAPPING
Cause
A Fibre Channel Adapter or NonStop Storage CLIM error has occurred during system load.
Effect
The processor load fails; the processor remains halted.
H-Series and J-Series Codes 61