Processor Halt Codes Manual
Effect
The processor halts. The rest of the system is unaffected.
Recovery
Refer to Processor Halt Monitoring and Recovery (page 10). Take a memory dump and contact
your service provider or the Global NonStop Solution Center (GNSC), as directed by your local
operating procedures.
%102402 MC_FAULT_TOTAL_LOCK_BREAKDOWN
Cause
Millicode detected a total breakdown associated with a MUTEX lock.
Effect
The processor halts. The rest of the system is unaffected.
Recovery
Refer to Processor Halt Monitoring and Recovery (page 10). Take a memory dump and contact
your service provider or the Global NonStop Solution Center (GNSC), as directed by your local
operating procedures.
%102403 MC_FAULT_MUTEX_OFF_FAILURE
Cause
Millicode detected a failure associated with releasing the MUTEX lock.
Effect
The processor halts. The rest of the system is unaffected.
Recovery
Refer to Processor Halt Monitoring and Recovery (page 10). Take a memory dump and contact
your service provider or the Global NonStop Solution Center (GNSC), as directed by your local
operating procedures.
%102404 MC_FAULT_INITIALIZE_LOCK_FAILURE
Cause
Millicode detected a failure associated with initializing the privileged lock (alignment problem).
Effect
The processor halts. The rest of the system is unaffected.
Recovery
Refer to Processor Halt Monitoring and Recovery (page 10). Take a memory dump and contact
your service provider or the Global NonStop Solution Center (GNSC), as directed by your local
operating procedures.
%102405 MC_FAULT_RECURSIVE_LOCK_ERROR
Cause
Millicode detected an error associated with recursive use of the lock by the process that owns
the lock.
Effect
The processor halts. The rest of the system is unaffected.
Recovery
Refer to Processor Halt Monitoring and Recovery (page 10). Take a memory dump and contact
your service provider or the Global NonStop Solution Center (GNSC), as directed by your local
operating procedures.
H-Series and J-Series Codes 71