%102471 MC_FAULT_TNET_ASIC_ERR
Cause
Millicode detected an error associated with the ServerNet ASIC.
Effect
The processor halts. The rest of the system is unaffected.
Recovery
Refer to Processor Halt Monitoring and Recovery (page 10). Take a memory dump and contact
your service provider or the Global NonStop Solution Center (GNSC), as directed by your local
operating procedures.
%102472 MC_FAULT_DBGFLT_NO_MTCB
Cause
Millicode has taken a Data Debug Fault (probably for a Memory Access Breakpoint), but there
is no current MTCB pointer.
Effect
The processor halts. The rest of the system is unaffected.
Recovery
Refer to Processor Halt Monitoring and Recovery (page 10). Take a memory dump and contact
your service provider or the Global NonStop Solution Center (GNSC), as directed by your local
operating procedures.
%102473 MC_FAULT_MABSSTEPTRAP
Cause
Millicode detected a Memory Access Breakpoint single-step trap.
Effect
The processor halts. The rest of the system is unaffected.
Recovery
Refer to Processor Halt Monitoring and Recovery (page 10). Take a memory dump and contact
your service provider or the Global NonStop Solution Center (GNSC), as directed by your local
operating procedures.
%102474 MC_FAULT_MABNOMTCB
Cause
Millicode detected a Memory Access Breakpoint but there is no current MTCB pointer.
Effect
The processor halts. The rest of the system is unaffected.
Recovery
Refer to Processor Halt Monitoring and Recovery (page 10). Take a memory dump and contact
your service provider or the Global NonStop Solution Center (GNSC), as directed by your local
operating procedures.
%102475 MC_FAULT_DIRTY_FLT
Cause
Millicode detected that the referenced data translation did not have the dirty-bit set, but a write
operation was done to this page.
Effect
The processor halts. The rest of the system is unaffected.
H-Series and J-Series Codes 83