Processor Halt Codes Manual

Recovery
Refer to Processor Halt Monitoring and Recovery (page 10). Take a memory dump and contact
your service provider or the Global NonStop Solution Center (GNSC), as directed by your local
operating procedures.
%102476 MC_FAULT_NSAA_INCONSISTENT_PTE
Cause
The millicode detected inconsistent bits (besides the dirty and referenced bits) in the page table
entries for the memory of an uncooperative process.
Effect
The processor halts. The rest of the system is unaffected.
Recovery
Refer to Processor Halt Monitoring and Recovery (page 10). Take a memory dump and contact
your service provider or the Global NonStop Solution Center (GNSC), as directed by your local
operating procedures.
%102477 MC_FAULT_NSAA_MEASURE_ADDR_ERROR
Cause
Millicode detected an error when attempting to add memory to the pool of a timer cell.
Effect
The processor halts. The rest of the system is unaffected.
Recovery
Refer to Processor Halt Monitoring and Recovery (page 10). Take a memory dump and contact
your service provider or the Global NonStop Solution Center (GNSC), as directed by your local
operating procedures.
%102500 MC_FAULT_PAGE_FAULT_ON_PRIV_RSE_STACK
Cause
Millicode detected page fault on the RSE stack for a process that is privileged.
Effect
The processor halts. The rest of the system is unaffected.
Recovery
Refer to Processor Halt Monitoring and Recovery (page 10). Take a memory dump and contact
your service provider or the Global NonStop Solution Center (GNSC), as directed by your local
operating procedures.
%102501 MC_FAULT_NESTED_INTERRUPT
Cause
Millicode detected a nested interrupt.
Effect
The processor halts. The rest of the system is unaffected.
Recovery
Refer to Processor Halt Monitoring and Recovery (page 10). Take a memory dump and contact
your service provider or the Global NonStop Solution Center (GNSC), as directed by your local
operating procedures.
%102502 MC_FAULT_LOWER_FRS_DISABLED
84 Millicode Halt Code Descriptions