Processor Halt Codes Manual

Cause
Millicode detected a fault that the lower FRs are disabled. These FRs should always be enabled.
Effect
The processor halts. The rest of the system is unaffected.
Recovery
Refer to Processor Halt Monitoring and Recovery (page 10). Take a memory dump and contact
your service provider or the Global NonStop Solution Center (GNSC), as directed by your local
operating procedures.
%102503 MC_FAULT_FPSA_FAILURE
Cause
Millicode detected a floating point software assist failure.
Effect
The processor halts. The rest of the system is unaffected.
Recovery
Refer to Processor Halt Monitoring and Recovery (page 10). Take a memory dump and contact
your service provider or the Global NonStop Solution Center (GNSC), as directed by your local
operating procedures.
%102504 MC_FAULT_NSK_BAD_IPADRRESS
Cause
Millicode detected a bad ServerNet BTE queue address.
Effect
The processor halts. The rest of the system is unaffected.
Recovery
Refer to Processor Halt Monitoring and Recovery (page 10). Take a memory dump and contact
your service provider or the Global NonStop Solution Center (GNSC), as directed by your local
operating procedures.
%102505 MC_BREAKPOINT_AT_INIT_TIME
Cause
Millicode detected a breakpoint at initialization time.
Effect
The processor halts. The rest of the system is unaffected.
Recovery
Refer to Processor Halt Monitoring and Recovery (page 10). Take a memory dump and contact
your service provider or the Global NonStop Solution Center (GNSC), as directed by your local
operating procedures.
%102506 MC_FAULT_SM_ATTN_RECEIVED
Cause
Millicode detected the receipt of an attention notification.
Effect
The processor halts. The rest of the system is unaffected.
H-Series and J-Series Codes 85