ProCurve Series 2300 and 2500 Switches Release Notes

247
Software Fixes
Release F.05.13 (Beta Release Only)
Adds the following enhancement:
Changes to Isolated Port Groups to add two new groups: group1 and group2.
Release F.05.15 (Beta Release Only)
Adds the following enhancements:
Increased IGMP V3 interoperability by allowing the switch to keep (and not prune) V3 groups.
This lets the switch interoperate in an IGMP V3 environment without pruning off the V3
groups (due to the Data-Driven IGMP feature) or always flooding.
Display the IGMP Querier in the output of the CLI show ip igmp command.
Fixed in release F.05.15
Bcast limit — Configuring broadcast limiting does not take effect until a reboot.
CDP — When CDP is disabled, the switch does not forward CDP packets.
Configuration file — In the configuration file, the command:
port-security 1 learn-mode continuous action send-alarm
results in this error message:
Inconsistent Value
Configuration file — In the configuration file, a command, such as:
port-security 1 learn-mode continuous action send-alarm
results in this error message: Inconsistent Value.
Counters — Counters reset when you hot-swap a Gig-T transceiver.
Counters — The Switch does not distinguish between CRC and alignment errors.
Crash — When setting the host name to a very long (~20 characters) string, the switch may
crash with a bus error similar to:
-> Bus error: HW Addr=0x29283030 IP=0x002086ac Task='mSnmpCtrl'
Task ID=0x165ae00.
Flow control — Users are allowed to configure flow control for half-duplex ports, even
though the switch does not support flow control ("back pressure") for half-duplex links.
Flow control — Users are allowed to configure 802.3x flow control for half-duplex ports.