ProCurve Switches 2524, 2512, and 4108gl Command Line Interface Reference Guide
2.12.2  SNMP commands – Configuration Level 
[no] snmp-server community <community-name> 
[manager | operator] 
[restricted | unrestricted] 
Used to configure a new SNMP community or to edit the configuration for an 
existing one 
Parameters: 
  <community-name> - Enter (up to 16 characters) the SNMP community name. 
  [manager | operator] - Manager - the community can access all MIB objects; 
Operator - the community can access all except the CONFIG MIB. 
  [restricted | unrestricted] - Unrestricted - any MIB variable that has read/write 
access can be set; Restricted - MIB variables cannot be set, only read. 
[no] snmp-server host  <ip-addr> <community-name> [none | all | non-info | critical  | 
debug] 
Configures which network management stations will receive SNMP event log 
messages from the switch and the types of events for which the switch will send 
these messages. 
Parameters: 
  <ip-addr> - Address of the network management station. 
  <community-name> - The name of the SNMP community to which the network 
management station belongs. 
  [none | all | non-info | critical | debug] - The level of Switch events that will 
generate a Trap to be sent: None - send no log message; All - send all log 
messages; Not INFO - send each log message that is not informational-only; 
Critical - send critical-level log messages; Debug (reserved for Internal use). 
[no] snmp-server enable traps authentication 
Enables authentication traps to be sent when a management station attempts an 
unauthorized access. 
35 