PTrace Reference Manual
Errors, Warnings, and Informational Messages
PTrace Reference Manual—526393-001
C-7
Nonfatal Errors
$SYSTEM.SYSTEM.ZPTRLIB, and the other references a library other than
$SYSTEM.SYSTEM.ZPTRLIB.
Recommended Action. Exit PTrace. Secure the product with the write access. Set
the TACL parameter PTRACE^LIB^MOVED to YES. Restart PTrace and reissue the
command.
Cause. An error occurred when trying to do a Process_getinfolist_ on the referenced
product module.
Recommended Action. Refer to the error codes returned by the Process_getinfolist_
and correct the problem.
Cause. The PTrace kernel could not open its $RECEIVE file.
Recommended Action. Check that the OPEN call to the $RECEIVE has been
correctly set up. If it has, then restart PTrace.
Cause. The PTrace kernel is for some reason unable to determine the home terminal
specified in the RUN command.
Recommended Action. Run PTrace specifying a different home terminal name.
Cause. PTRACE was able to run a new process with the product module but for some
reason is unable to open the product module.
Recommended Action. Refer to the Guardian error number, correct the problem,
and retry the command.
Cause. An invalid record number was specified in the RECORD command.
Recommended Action. The record number specified in the RECORD command must
be greater than or equal to 0 and must fit in 32-bit integer format.
PTRACE Product module, \System.$vol.subvol.ZsubsysPTR stopped
PROCESS_GETINFOLIST_error error#.
PTRACE $RECEIVE error on open, ABORTING.
PTRACE is unable to determine hometerm, ABORTING.
PTRACE is unable to open Product Module,
\System.$vol.subvol.subsys, Guardian Error nn.
Specified trace record number invalid.