RDF System Management Manual

Table Of Contents
Process-Lockstep Operation
HP NonStop RDF System Management Manual524388-003
14-9
Lockstep Operation Event Messages
2
Cause. You are missing either the ENABLE/DISABLE argument, or you have not
specified the name of the RDF extractor.
Effect. The lockstep gateway stops.
Recovery. In your SCF script for starting the lockstep gateway, you must specify
either ENABLE or DISABLE and the RDF extractor process name with the
STARTUPMSG attribute. Note that the process name must not include a node name.
3
Cause. You did not specify ENABLE or DISABLE as the first argument of the
STARTUPMSG attribute in your SCF script.
Effect. The lockstep gateway stops.
Recovery. In your SCF script for starting the lockstep gateway, you must specify
either ENABLE or DISABLE as the first argument of the STARTUPMSG attribute.
4
errnum
is a file-system error number.
procname
is the name of an extractor process.
Cause. The RDF extractor is no longer responding, and it may be stopped.
Effect. The lockstep gateway stops.
Recovery. Determine why the RDF subsystem stopped, correct the problem, and then
restart the subsystem.
A STARTUPMSG argument is missing for the lockstep gateway.
The first argument of the STARTUPMSG attribute for your
lockstep gateway was neither ENABLE nor DISABLE.
The lockstep gateway has received error errnum when
attempting to communicate with the RDF extractor procname.