HP NonStop RDF System Management Manual524388-003
C-21
RDF Messages
750
Cause. All RDF processes rely upon the ability to post timers by calling
SIGNALTIMEOUT and take action when those timers expire. This message indicates
that a call to SIGNALTIMEOUT failed because there were insufficient time list elements
(TLEs) available.
Effect. The process continues to run, but recovery is required.
Recovery. Issue a STOP RDF command immediately. Then investigate why there is
a shortage of TLEs in the CPU of the RDF process that could not obtain one. If you
want to start RDF again while conducting this investigation, you should alter the RDF
configuration of the process that could not obtain the TLE, specifying a different set of
CPUs.
751
error
is the file-system error number that identifies the specific error.
filename
is the name of the file associated with the error.
Cause. A call to the FILE_OPEN_CHKPT_ procedure failed, and the backup process
of a process pair is still running. The message includes the file-system error number
encountered when the primary process attempted to communicate with the backup
process and the name of the file associated with the error.
Effect. The backup process is stopped, and a new one is created after about
15 seconds.
Recovery. Consult the description of the FILE_OPEN_CHKPT_ procedure in the
Guardian Procedure Calls Reference Manual to determine the cause of the failure. If
possible, correct the underlying cause to avoid its reoccurrence.
752
filename
is the name of the audit-trail file that contained the error.
Failure to obtain TLE for SIGNALTIMEOUT
FILE_OPEN_CHKPT_ error error on filename
Audit block RBN out of sequence. File filename RBN rbn RBA
rba