RDF/IMP and IMPX System Management Manual (RDF 1.3+)
Entering RDFCOM Commands
Compaq NonStop™ RDF/IMP and IMPX System Management Manual—522204-001
8-89
Command Overview
For more information on critical errors, you can scan the EMS collectors on the primary
and backup systems:
•
The EMS collector on the primary system contains log messages for the extractor
and monitor processes.
•
The EMS collector on the backup system contains log messages for the receiver,
purger, and all updater processes.
Special Messages
If you issue the STATUS RDF command while an RDF TAKEOVER operation is in
progress, RDF displays the current state as “TAKEOVER IN PROGRESS.”
If you issue the STATUS RDF command after an RDF TAKEOVER operation has
completed, RDFCOM displays the following message instead of the usual status
display:
STATUS RDF (\primary -> \backup) is NOT running.
An RDF TAKEOVER has completed.
Examples
To display current RDF configuration information and operational statistics once, enter
the following command:
]STATUS RDF
To display that information 10 times, once every minute, enter:
]STATUS RDF, PERIOD 60, COUNT 10
To display current information and statistics for all configured extractor processes once,
enter the following command:
]STATUS EXTRACTOR
To display current information and statistics for only those processes (the extractors or
any updater) that have fallen behind the configured RTD threshold (rtd-time), enter the
following command:
]STATUS RTDWARNING