RDF/IMP and IMPX System Management Manual (RDF 1.3+)
Messages
Compaq NonStop™ RDF/IMP and IMPX System Management Manual—522204-001
C-6
RDF Messages
710
Cause. An RDF process tried to obtain audit trail information from the TMF
management process pair (TMP) on the primary system, but the TMP was not
accessible. The probable cause is that TMF is not currently running. RDF requires that
TMF be up and running on the primary and all backup nodes.
Effect. The RDF process abends.
Recovery. Start TMF on the primary node.
711
error#
is the file-system error number that identifies the specific error.
Cause. A fatal RDF error occurred: an updater failed to obtain process information
about itself.
Effect. The updater process abends.
Recovery. This is an internal error. Contact your service provider.
712
nnn nnn
are the upper and lower bytes, respectively, of the status code reported by the
NEWPROCESS procedure.
filename
is the name of the program file that was to be executed.
Cause. The monitor encountered an error while attempting to create an RDF process.
The error fields reported in the message are the upper and lower bytes of the status
returned by the NEWPROCESS system procedure followed by the filename of the
program that was to be run.
Effect. The process is not started, and RDF shuts down.
Recovery. Consult the description of the NEWPROCESS procedure errors in the
Guardian Procedure Errors and Messages Manual to determine the cause of the failure.
Once the underlying cause is corrected, RDF can be restarted.
TMP is inaccessible
Failure to get process info - error: error#
Process Creation Error: nnn nnn filename