RDF/IMP and IMPX System Management Manual (RDF 1.3+)

Messages
Compaq NonStop™ RDF/IMP and IMPX System Management Manual522204-001
C-15
RDF Messages
736
error#
is the file-system error number that identifies the specific error.
filename
is the name of the file that caused the error.
Cause. The updater could not obtain information about the specified file. Before an
updater can apply audit records to a file, it must obtain information about the file. The
probable reason why information could not be obtained is that the file has not been
created yet.
Effect. The updater delays for 30 seconds and then tries to obtain the information again.
Recovery. If the specified file is an SQL table, then you must create that table on the
remote node.
If the specified file is an Enscribe file, the file may not exist on the RDF backup node
yet. If you have just created the file on the primary node, then the updater has probably
sent the creation audit record to the disk process, but the file has not yet been created. In
this case, this message is informational; when the file is created, the updater will be able
to obtain the information it needs and continue processing.
737
Cause. When the extractor is starting or restarting, it sends a request to the receiver to
obtain its starting position in the TMF Master Audit Trail (MAT). The extractor issues
error 737, indicating that the extractor is attempting to become synchronized with the
receiver by requesting this starting position.
Effect. The extractor attempts to become synchronized with the receiver.
Recovery. This is an informational message; no recovery is required.
Waiting to obtain fileinfo on error# filename
Extractor establishing synch