RDF/IMP and IMPX System Management Manual (RDF 1.3+)

Messages
Compaq NonStop™ RDF/IMP and IMPX System Management Manual522204-001
C-20
RDF Messages
750
Cause. All RDF processes rely upon the ability to post timers by calling
SIGNALTIMEOUT and take action when those timers expire. This message indicates
that a call to SIGNALTIMEOUT failed because there were insufficient time list
elements (TLEs) available.
Effect. The process continues to run, but recovery is required.
Recovery. Issue a STOP RDF command immediately. Then investigate why there is a
shortage of TLEs in the CPU of the RDF process that could not obtain one. If you want
to start RDF again while conducting this investigation, you should alter the RDF
configuration of the process that could not obtain the TLE, specifying a different set of
CPUs for that process.
751
error#
is the file-system error number that identifies the specific error.
filename
is the name of the file associated with the error.
Cause. A call to the CHECKOPEN procedure failed, and the backup process of a
process pair is still running. The message includes the file-system error number
encountered when the primary process tried to communicate with the backup process
and the name of the file associated with the error.
Effect. The backup process is stopped, and a new one is created after about 15 seconds.
Recovery. This is an informational message; no recovery is required. Consult the
description of the CHECKPOINT procedure errors in the Guardian Procedure Errors
and Messages Manual to determine the cause of the failure. If possible, correct the
underlying cause to avoid its reoccurrence.
Failure to obtain TLE for Signaltimeout
CHECKOPEN Error error# filename