RDF/IMP and IMPX System Management Manual (RDF 1.3+)

Messages
Compaq NonStop™ RDF/IMP and IMPX System Management Manual522204-001
C-30
RDF Messages
783
Cause. The monitor or extractor process could not open the remote receiver process
after a communications failure.
Effect. If the monitor or extractor process receives a file-system error 14 (process does
not exist), RDF will shut down on the primary node.
Recovery. If RDF was stopped on the remote node by a STOP RDF command while the
communications lines were down, simply restart RDF by issuing a START RDF
command.
784
timestamp
is the specified timestamp.
Cause. The operator issued an RDFCOM STOP UPDATE, TIMESTAMP command at
the primary node.
Effect. The RDF updaters stop when they have processed all image records for all
transactions that complete by the specified time.
Recovery. This is an informational message; no recovery is required.
785
timestamp
is the timestamp specified previously by an operator in an RDFCOM STOP
UPDATE, TIMESTAMP command.
Cause. In response to a STOP UPDATE, TIMESTAMP command, the updater has
completed its redo pass.
Effect. The updater is ready to commence its undo pass.
Recovery. This is an informational message; no recovery is required.
RECEIVER process is not running
Shutdown pending STOP UPDATE, TIMESTAMP timestamp
Redo pass ending on reaching TIMESTAMP timestamp