RDF/IMP and IMPX System Management Manual (RDF 1.3+)
Messages
Compaq NonStop™ RDF/IMP and IMPX System Management Manual—522204-001
C-125
RDFCOM Messages
Effect. The COPYAUDIT command aborts.
Recovery. Refer to the Operator Messages Manual for a description of the error code.
For additional details about understanding and correcting file-system errors, see the
Guardian Procedure Errors and Messages Manual. If possible, correct the error and
reenter the COPYAUDIT command. Otherwise, see your system manager.
remote-system
is the name of the RDF backup system that received the most audit.
local-system
is the name of the local RDF system that received the least audit.
Cause. You entered a COPYAUDIT command and receive this message as a prompt for
confirmation that you wish to proceed with the command’s execution.
Effect. If you respond YES or Y, RDF executes the command. If you respond NO or N,
the command terminates.
Recovery. This is an informational message; no recovery is required.
Cause. You have asked RDFCOM to unpin a file that is currently needed by the
extractor. If you respond “yes,” the file is unpinned and TMF can rename it. If the file
is renamed, RDF cannot be restarted until you restore the file.
Effect. RDFCOM suspends until you respond to the prompt.
Recovery. Respond “yes” or “no” to the prompt.
Cause. RDFCOM has detected that the receiver stopped prematurely the last time it
was running. Because you are attempting the takeover operation before RDF has been
allowed to restart, the probability is high that your database is already inconsistent with
respect to transaction boundaries. That is, for some transactions, all audit data might not
have been applied to database.
Effect. The database might be inconsistent.
You are about to copy audit information from remote-system to
local-system
Are you sure you want to proceed [Y/N] ?
You are about to unpin a file that the extractor needs. Are
you sure you want to proceed?
You are attempting a TAKEOVER operation immediately after the
receiver has crashed. Please contact your Tandem analyst