RDF/IMP and IMPX System Management Manual (RDF 1.4+)
Online Database Synchronization
HP NonStop RDF/IMP and IMPX System Management Manual—524388-001
7-23
When Is Online Database Synchronization
Complete?
•
If the restart condition occurs after phase 1 has begun, the extractor may choose to 
resume at an earlier position than the receiver tells it to. It does this to ensure that 
it has handled all committed and aborted transactions correctly. If the extractor 
does resume at an earlier position, it logs message 775. Additionally, regardless of 
whether or not it adjusted the restart position, the extractor may log messages 766, 
767, and 768 again, even if it had logged any of them prior to the restart condition.
When Is Online Database Synchronization 
Complete?
The following RDF messages assist you in knowing when the various phases of online 
database synchronization are complete:
Extractor Messages
Messages 766, 767, and 768 in combination report the completion of phase 1. 
Message 782 reports the completion of phase 2.  Message 782 indicates that the 
extractor has finished its involvement in the online synchronization operation.
Updater Messages
Message 782 reports the completion of phase 2 and indicates that the updater has 
finished its involvement in the online synchronization operation. Please note that even 
in a partial database synchronization, all updaters will log event 782 because, in a 
partial database synchronization, you follow the guildelines of a complete database 
synchronization, except that you are only loading the specific volumes, table, and files 
you need. Therefore all updaters log the 782 event.
Additionally, the STATUS RDF display has been enhanced to identify which database 
volumes are still being synchronized. That information is reported in the error column 
of the display. If a volume is still being synchronized, its entry in the error column is 
sync. As soon as a volume is successfully synchronized, its entry in the error column 
is blank. If an updater encounters an error during synchronization, the associated 
entry in the error column is ****.
The following sample display shows that the updater process $MUP1 for the data 
volume $DATA1 has successfully completed synchronization while the updater process 
$MUP2 for the data volume $DATA2 is still doing the synchronization:
RDF Process    Name RTD Time  Pri Volume  Seqnce RByte Addr Cpus Error
-------------------- ----- --------- --- ------- ------ ---------- ----- -----
Monitor      $MMON      185 $TRAILS 5       2:3
Extractor (0)     $MEXT   0:00  185 $TRAILS  5  7110636  2:3
Receiver (0)   $MRCV  0:00 185 $TRAILS  37  806912 1:2
$DATA1 -> $DATA2   $MUP1   0:00 185 $TRAILS 37  806912 1:2
$DATA2 -> $DATA3   $MUP2   1:58 185 $TRAILS 32  712704 1:2 sync