RDF/IMP and IMPX System Management Manual (RDF 1.4+)
Lockstep Operation
HP NonStop RDF/IMP and IMPX System Management Manual—524388-001
14-19
Lockstep Operation Event Messages
30 
errnum
is a file-system error number.
Cause. The specified error was encountered on ENDTRANSACTION.
Effect. If the error is retryable, the lockstep gateway starts a new transaction. If the 
error is unexpected, the gateway stops.
Recovery. This is an informational error, unless the gateway stops. If it stops, correct 
the condition that caused the error and then restart the gateway.
31 
procname
is the invalid process name.
Cause. In your SCF script for starting the lockstep gateway, the process name 
specified in the STARTUPMSG attribute was not a valid process name for the RDF 
master extractor.
Effect. The lockstep gateway stops.
Recovery. Correct the STARTUPMSG attribute script and then manually delete the 
RDF lockstep gateway process from SCF and run your newly edited SCF script. Note 
that the process name must not include a node name.
32 
Cause. In your SCF script for starting the lockstep gateway, the STARTUPMSG 
attribute contained an extra or unrecognizable argument.
Effect. The lockstep gateway stops.
Recovery. The STARTUPMSG attribute must include exactly two arguments: the word 
ENABLE or DISABLE, and a valid RDF extractor process name, all enclosed in quotes. 
Correct the STARTUPMSG attribute script and then manually delete the RDF lockstep 
gateway process from SCF and run your newly edited SCF script. Note that the 
process name must not include a node name.
ENDTRANSACTION error errnum encountered on lockstep 
transaction.
Invalid process name: procname for the RDF master extractor.
A spurious STARTUPMSG argument was encountered for the 
lockstep gateway.