Lockstep Operation Event Messages
30
errnum
is a file-system error number.
Cause. The specified error was encountered on ENDTRANSACTION.
Effect. If the error is retryable, the lockstep gateway starts a new transaction. If the
error is unexpected, the gateway stops.
Recovery. This is an informational error, unless the gateway stops. If it stops, correct
the condition that caused the error and then restart the gateway.
31
procname
is the invalid process name.
Cause. In your SCF script for starting the lockstep gateway, the process name
specified in the STARTUPMSG attribute was not a valid process name for the RDF
master extractor.
Effect. The lockstep gateway stops.
Recovery. Correct the STARTUPMSG attribute script and then manually delete the
RDF lockstep gateway process from SCF and run your newly edited SCF script. Note
that the process name must not include a node name.
32
Cause. In your SCF script for starting the lockstep gateway, the STARTUPMSG
attribute contained an extra or unrecognizable argument.
Effect. The lockstep gateway stops.
Recovery. The STARTUPMSG attribute must include exactly two arguments: the
word ENABLE or DISABLE, and a valid RDF extractor process name, all enclosed in
quotes. Correct the STARTUPMSG attribute script and then manually delete the RDF
lockstep gateway process from SCF and run your newly edited SCF script. Note that
the process name must not include a node name.
ENDTRANSACTION error errnum encountered on lockstep
transaction.
Invalid process name: procname for the RDF master extractor.
A spurious STARTUPMSG argument was encountered for the
lockstep gateway.