RDF/IMP, IMPX, and ZLT System Management Manual
Messages
HP NonStop RDF/IMP, IMPX, and ZLT System Management Manual—524388-002
C-9
RDF Messages
Effect. The backup process takes over, but not in fault-tolerant mode, until the primary
process can be re-created.
Recovery. Scan the EMS event log to determine why the process abended. An
INSPECT SAVEABEND file should have been created in the volume and subvolume
where you placed the RDF software. You should save that file for problem resolution
by your service provider.
717
Cause. The primary CPU of a process pair has stopped.
Effect. The backup process takes over, but not in fault-tolerant mode. The primary
process will be re-created after its CPU is reloaded.
Recovery. Reload the downed processor.
718
Cause. The original backup process of a process pair has successfully created a
backup process in the configured primary processor and has successfully switched
processing to that process.
Effect. The process pair is switching primary and backup roles so that the primary
process is now running in the CPU configured as the primary processor.
Recovery. Informational message only; no corrective action is needed.
719
nnn
is the status word returned by CHECKPOINT.
Cause. A CHECKPOINT call from the primary process of a process pair to its backup
process failed because of a parameter error. This message indicates a programming
problem within RDF. The message includes the status word returned by the
CHECKPOINT procedure.
Effect. The backup process is stopped, and a new one is created after about
15 seconds.
Recovery. Informational message only; no corrective action is needed. You should,
however, contact your service provider and explain that this error occurred.
Primary processor down
Switched to original primary processor
Bad parameter in CHECKPOINT - status nnn