RDF/IMP, IMPX, and ZLT System Management Manual
Messages
HP NonStop RDF/IMP, IMPX, and ZLT System Management Manual—524388-002
C-21
RDF Messages
751
error
is the file-system error number that identifies the specific error.
filename
is the name of the file associated with the error.
Cause. A call to the CHECKOPEN procedure failed, and the backup process of a
process pair is still running. The message includes the file-system error number
encountered when the primary process tried to communicate with the backup process
and the name of the file associated with the error.
Effect. The backup process is stopped, and a new one is created after about
15 seconds.
Recovery. Informational message only; no corrective action is needed. Consult the
description of the CHECKPOINT procedure errors in the Guardian Procedure Calls
Reference Manual to determine the cause of the failure. If possible, correct the
underlying cause to avoid its reoccurrence.
752
filename
is the name of the audit trail file that contained the error.
rbn
is the relative block number of the block where the error occurred in the audit trail
file.
rba
is the relative byte address where the error occurred in the audit trail file.
Cause. The extractor detected that the relative block number (RBN) of a block of audit
data in the TMF audit trail is out of sequence.
Effect. This is a catastrophic error; the extractor abends, and RDF stops.
Recovery. This message indicates an internal RDF or TMF error. You must
resynchronize the primary and backup databases. Save the audit trail file, and report
this error to your service provider.
CHECKOPEN Error error On filename
Audit block RBN out of sequence. File filename RBN rbn RBA
rba