RSC/MP 7.2 Messages Manual

Messages Reported From the Host
HP NonStop Remote Server Call (RSC/MP) Messages Manual522359-004
2-32
3045
Cause. An object SET or ALTER command was issued without an attribute argument.
Effect. The command is rejected.
Recovery. See the Remote Server Call (RSC/MP) Installation and Configuration
Guide for the correct command syntax and reissue the command if appropriate.
3046
Cause. An object SET or ALTER command was issued with an attribute that is not
valid for the specified object.
Effect. The command is rejected.
Recovery. See the Remote Server Call (RSC/MP) Installation and Configuration
Guide for a list of valid attributes for each object and reissue the command if
appropriate.
3047
Cause. A START, STOP, or ABORT command was issued on a TERM object that is
configured as a template.
Effect. The command is rejected.
Recovery. This message is informational only. No corrective action is necessary.
3049
Cause. The specified attribute name is too long.
Effect. The command fails.
Recovery. Reissue the command with a valid attribute name.
*** Error 3045: You must supply a valid attribute type.
*** Error 3046: Attribute <name> is not valid for this object
type.
*** Warning 3047: TERM <term name> is configured as a
template. Its object state cannot be altered.
*** Error 3049: <attribute name> is limited to <count>
characters.