RSC/MP 7.3 Installation and Configuration Guide
Asynchronous Network Interface Configuration
HP NonStop Remote Server Call (RSC/MP) Installation and Configuration Guide—522358-011
7-9
Network Interface Section ([NIF-nifname])
FlowControl Option
The FlowControl option defines the flow control method to be used on the link. There
are three options:
•
Hardware Use RTS/CTS flow control; your hardware must be set up for flow
control
•
Software Use XON/XOFF flow control
•
None Do not use flow control
Required: No
Default: NONE
Platforms: All
Examples:
1. FlowControl=hardware
2. FlowControl=software
3. FlowControl=none
IdleDisconnect Option
The IdleDisconnect option specifies the number of seconds that a physical network
connection will be maintained when no logical pipes are using the connection.
number
The number of seconds in the range 5 through 65535.
Required: No
Default: 5 seconds.
Platforms: All
Example:
IdleDisconnect=180
FlowControl=HARDWARE | SOFTWARE | NONE
Note. If you specify HARDWARE flow control on the NonStop system, you must enable
CTSFLOW using CMI or SCF, or flow control on any other device.
IdleDisconnect=number