RSC/MP 7.3 Installation and Configuration Guide
RSCCOM Command Reference
HP NonStop Remote Server Call (RSC/MP) Installation and Configuration Guide—522358-010
13-29
PIPE Object Attributes
PIPE Object Attributes
For PIPE objects, the object name must be unique in the TDP, but does not need to be
unique on the host or on the network. Piccolo distributes connections across PIPE
objects of the same name in the same host. The name must match the first portion of
the HOST_PIPENAME option on the workstation.
Table 13-2. PIPE Object Attributes
Attribute Name Description
AUTORESTART
The number of seconds to wait before automatically restarting a
PIPE object that was aborted because of an error. The default
value is 30 seconds. Use the SET AUTORESTART command to
automatically restart an aborted PIPE object.
You can alter the AUTORESTART attribute without the PIPE
object being in the STOPPED state.
KEEPALIVE
The number of seconds between attempts by Piccolo to verify
that the connection remains active. The value may be from zero
(disabled) to 360000 seconds (100 hours). Low values for
KEEPALIVE may burden networks with verification messages.
By default, KEEPALIVE is disabled (0).
The PIPE object must be in the STOPPED state before using
the ALTER command with the KEEPALIVE attribute
LOGEVENTS
The type of logging event. This attribute is used primarily for
RSC/MP development and debugging and is subject to change.
You can use the LOGEVENTS attribute without the PIPE object
being in the STOPPED state.