RSC/MP 7.3 Installation and Configuration Guide

Best Practices Guide
HP NonStop Remote Server Call (RSC/MP) Installation and Configuration Guide522358-011
F-10
Scenario 3
Scenario 3
In a critical production environment where redundancy and high performance are major
requirements, two separate networks might be used (different wires, switches, hubs,
routers, and so on). In this case, a configuration similar to the following can be used
(see Figure F-7).
Figure F-7. Scenario 3
Servers
Servers
Servers
NonStop host
HOST1
CDT018
TDP
PIPEMAN
NIF
TDP
NIF NIFNIF
$ZTC0 $ZTC1 $ZTC2 $ZTC3
TDP
PIPEMAN
Application
NIF
RSCPIPE
workstation
(group “B”)
workstation
(group “A”)
PIPEMAN
Application
NIF
RSCPIPE
10.2.90.21
10.1.90.2110.2.90.2010.1.90.20
PIPEMAN
TDP
SystemName
HOST1B
SystemName
HOST1A
“A” alternate
“A” primary
“B” primary
B
a
l
t
e
r
n
a
t
e
Network X
Network Y
Group B workstations have
[RESOLVER]
HOST1=ip:10.2.90.21,ip:10.1.90.21
Group A workstations have
[RESOLVER]
HOST1=ip:10.1.90.20,ip:10.2.90.20
X Y X Y