RSC/MP 7.3 Installation and Configuration Guide

Configuring the RSC/MP Transport (Piccolo)
HP NonStop Remote Server Call (RSC/MP) Installation and Configuration Guide522358-011
5-35
Pipeman Section ([PIPEMAN])
Default: 3
Platforms: All
Example:
T1Retries=10
T2Interval Option
The T2Interval option defines the maximum number of seconds before a packet will be
explicitly acknowledged by Pipeman.
T1 and T2 are calculated by Pipeman based on the throughput rate of the messages.
interval
By strict definition, T2 is defined to be half the amount of time it takes to send a
message of maximum size and receive it back again together with any associated
processing time using Link Access Protocol Balance (LAPB). If the T2 timer
expires before a message is sent from the destination Piccolo to the source
Piccolo, the destination Piccolo will send a message with an explicit
acknowledgment to the source Piccolo. The valid range is an integer from 0
through 65535.
Required: No.
Default: 8
Platforms: All
Example:
T2Interval=10
Term Option
The Term option specifies the name of the home terminal for the Pipeman process.
terminalname
A valid name for a terminal or process (can also contain a node name).
Required: No.
Default: Home terminal name of the PIPECP that starts Pipeman.
Note. Do not alter this value unless instructed to do so by HP Global Customer Support
Center (GCSC).
T2Interval=interval
Term=terminalname