RSC/MP Installation and Configuration Guide

Installation Troubleshooting
Step 4. Check the Host Configuration
2. On a Windows workstation or a UNIX workstation, enter this command:
> pcfgchk
which should produce output similar to the following (line numbers and sections
processed vary depending on the data in the Piccolo Configuration file; VPROC
and configuration file names will vary depending on the platform):
Piccolo Configuration Check Program - T7981V70 - (28SEP2003) -
4.0.0/001 - Win32
Copyright (c) 1994-2003 Cornerstone Software, Inc. All rights
reserved.
Checking configuration file c:\rsc\bin\pipe.ini
Processing section [pipeman]
Processing complete for section [pipeman], (Lines 1 - 8).
Processing section [nif-tcp]
Processing complete for section [nif-tcp], (Lines 9 - 12).
Final processsing...
....processing complete.
3. If any error or warning is reported, refer to Creating the Configuration File (for all
installations) on page 5-10 to find information which may help determine the cause
of the problem. Modify the Piccolo Configuration file as needed to eliminate any
errors and warnings.
Step
4. Check the Host
Configuration
1. Verify that the appropriate TDP objects are started (for example, TERM and PIPE)
by entering the following command at a TACL prompt:
1>RSCCOM $TDP; STATUS TERM *
If the appropriate object is not started, verify your configuration files by entering the
following command at a TACL prompt:
2>RSCCOM $TDP; INFO TERM *
Verify that the appropriate object is configured and all named processes are
referenced correctly. Make any corrections and start the object, as required.
2. Ensure that the TDDSVR process is running as a named process $TDD on the
host. This is the process that echoes messages that the workstation test program
sends to the NonStop host. Enter the following command at a TACL prompt:
3>STATUS $TDD
HP NonStop Remote Server Call (RSC/MP) Installation and Configuration
G uide
52235 8- 013
B - 4