RSC/MP Installation and Configuration Guide
Introduction
Communications Protocols
Communications
Protocols
Ta ble 1-3 shows the communications protocols available for each RSC/MP product.
Table 1-3. RSC/MP Communication Protocols
Communication Protocol
Platform
TCP/IP
NetBIOS
UNIX
X
Win32
X
X
Win32+TSE
X
Windows Vista
X
RSC/MP
Installation
RSC/MP includes the following software:
Host software — Different versions of the host software exist for Integrity NonStop
servers and for NonStop S-series servers.
Workstation software — Each client platform requires specific software.
For new installations or upgrades, install the host software first, then install the
workstation software.
Note. If you are already running RSC/MP, back up all existing program and configuration files
before installing new software. You should read the host and workstation softdocs (provided as
files with the RSC/MP software) before installing the software.
General Steps for Installation
RSC/MP software installation includes these general steps:
1. Install the RSC/MP software on the NonStop host system.
2. Configure the host software for the communications protocol that you will use on
each client workstation.
3. Download the workstation software from the host to each workstation (see the
appropriate section for Windows or UNIX ).
4. Configure each workstation for the communications protocols that RSC/MP will use
(see the appropriate section for TCP/IP or NetBIOS).
HP NonStop Remote Server Call (RSC/MP) Installation and Configuration
G uide
—
52235 8- 013
1 -5