RSC/MP Installation and Configuration Guide

Installing RSC/MP on UNIX Workstations
Installing on Solaris From A CD
Installing
on Solaris from a CD
Note. The current version of RSC/MP supports multithreaded RSC/MP applications on
Solaris. Depending on the number of threads required by the application, it might be necessary
to adjust the Solaris system configuration in order to run the application. For more information,
refer to ―Thread Limitations on UNIX-based Operating Systems under the description of
RscRegisterThread in the Remote Server Call (RSC/MP) Programming Manual.
1. Insert the RSC/MP Solaris Client CD into a drive attached to a Windows
workstation.
2. Navigate to the WS_SW folder on the RSC/MP Client CD.
3. Locate the file RPSOLEXE.TAR.
4. Select one of these installation methods:
Transfer the TAR file to the UNIX workstation. The file must be transferred in
BINARY mode. Log on to the UNIX workstation, navigate to the directory
where the TAR file is stored, and type:
tar xvf RPSOLEXE.TAR
Transfer the TAR file to the NonStop and then transfer the TAR file to the UNIX
workstation. The file must be transferred in BINARY mode. Log on to the UNIX
workstation, navigate to the directory where the TAR file is stored, and type:
tar xvf RPSOLEXE.TAR
5. When installing on Solaris (SPARC), the RPSOLEXE.TAR file contains two
additional TAR files, RPSOL32EXE.TAR and RPSOL64EXE.TAR. These are the
TAR files containing the 32 and 64-bit clients respectively. Extract the desired client
by un-TARing the appropriate TAR file with the command:
tar xvf RPSOL32EXE.TAR or
tar xvf RPSOL64EXE.TAR
HP NonStop Remote Server Call (RSC/MP) Installation and Configuration
G uide
52235 8- 013
6 - 6