RSC/MP Messages Manual

Messages Reported From the Host
7305
ACS object not started due to an invalid configuration.
Cause. ACS attributes ACSSERVERCLASS and ACSPROCESSNAME have been
left blank.
Effect. The ACS cannot be started.
Recovery. Specify the server class and process name of the process associated with
the ACS object.
7306
File system error <error code> occurred while trying to open
Access Server Guardian 90 process.
Cause. An error occurred while trying to open the Access Server.
Effect. The Access Server is not opened. The RscBeginSession or RscWriteRead call
fails.
Recovery. Make sure the ACS object is correctly configured, and check the Access
Server for errors.
7307
ACS object received a message with an invalid tag.
Cause. The ACS object received a message with a tag that does no t match any tag
sent out.
Effect. There might be no effect, or an RscBeginSession or RscWriteRead call will
hang.
Recovery. Check the message the access control server passes to the ACS object.
8501
The TDP has tried to close a pipe with a null pipe handle.
Cause. Because of internal conditions, the PIPE object tried to shut down the
connection twice.
Effect. None.
Recovery. This message is informational only. No corrective action is necessary.
HP NonStop Remote Server Call (RSC/MP) Messages Manual 522359-006
2- 47