RSC/MP Programming Manual
API Option Definitions
RscWrite and RscWriteRead Function Options
RscWrite and RscWriteRead Function Options
This table shows the options for RscWrite and RscWriteRead functions.
Table D-4. Options for the RscWrite and RscWriteRead Functions (page 1 of 2)
Acceptable
Option Selector Type
Values Notes
ACS_BINARY_AREA CHAR * 1 to 128 byte
binary string
ACS_MESSAGE_AREA CHAR * 1 to 128
characters
Used to exchange binary data
with the ACS server when ACS
is implemented and
RECVWRITEREADS is set to
YES.
Used to exchange text data
with the ACS server when ACS
is implemented and
RECVWRITEREADS is set to
YES.
HOST_ACS_NAME CHAR * 1 to 30 characters A NULL-terminated string. Used
to specify the ACS object
server when ACS is
implemented.
OPEN_COUNT USHORT 1 to 64 Number of outstanding opens
by the TDP on the server. The
default is 15.
PASSWORD CHAR * 1 to 18 characters Used to communicate with the
ACS server when ACS is
implemented and
RECVWRITEREADS is set to
YES.
SETMODE_30 SHORT 0, 1 values only Value of 1 allows the server to
respond in any order to multiple
nowaited I/O operations.
SUCCESS_HI SHORT -32768 to 32767 See TMF Workstation Options
on page 6-8.
SUCCESS_LO SHORT -32768 to 32767 See TMF Workstation Options
on page 6-8.
SYNC_DEPTH USHORT 1 to 20; default is 1 See description in Ta ble D-1.
USER_ID CHAR * 1 to18 characters Used to communicate with the
ACS server when ACS is
implemented and
RECVWRITEREADS is set to
YES.
USER_NAME CHAR * 1 to 18 characters Synonym for USER_ID.
TMF_OPTION USHORT 0, 1, 2, or 3 See description in Ta ble 6-1.
HP NonStop Remote Server Call (RSC/MP) Programming Manual — 522360-006
D- 9