Safeguard Administrator's Manual (G06.29+, H06.08+, J06.03+)
Controlling User Access
Safeguard Administrator’s Manual—523317-029
2-10
Adding Users to the System
GUARDIAN DEFAULT 
SECURITY
Sets the Guardian default 
security string for a user. This 
security string is given to any 
of the user disk files that are 
not added to Safeguard.
The default value is OOOO.
However, when the 
Safeguard software is 
installed on an existing 
system, users keep their 
established Guardian default 
security. 
GUARDIAN DEFAULT 
VOLUME
Sets the Guardian default 
volume and subvolume for a 
user.
The default value is 
$SYSTEM.NOSUBVOL.
However, when the 
Safeguard software is 
installed on an existing 
system, users keep their 
established default volume 
and subvolume. 
CI-PROG Specifies the command 
interpreter to be started 
automatically after the user 
logs on at a terminal controlled 
by the Safeguard software.
The default value is no 
command interpreter. 
However, the CI-PROG 
global configuration attribute 
is set to 
$SYSTEM.SYSTEM.TACL. 
This value is used if no 
command interpreter is 
specified for the user or the 
Safeguard terminal.
CI-LIB Specifies the library to be used 
with the command interpreter 
started after the user logs on 
at a terminal controlled by the 
Safeguard software.
The default value is no 
library file. 
CI-NAME Specifies the process name to 
be given to the command 
interpreter started after the 
user logs on at a terminal 
controlled by the Safeguard 
software.
The default value is NONE.
The command interpreter is 
be given a random name of 
the form $Znnn.
CI-CPU Specifies the processor in 
which the command 
interpreter is to be started.
The default value is any 
CPU. 
Table 2-1. User Security Attributes and Default Attribute Values (page 4 of 5)
Attribute Description Default Value
1
 The STATIC-FAILED-LOGON-RESET-TIME attribute is supported only on systems running H06.10 and later 
H-series RVUs and G06.32 and later G-series RVUs.