Safeguard Administrator's Manual (G06.29+, H06.08+, J06.03+)

Controlling User Access
Safeguard Administrator’s Manual—523317-029
2-10
Adding Users to the System
GUARDIAN DEFAULT
SECURITY
Sets the Guardian default
security string for a user. This
security string is given to any
of the user disk files that are
not added to Safeguard.
The default value is OOOO.
However, when the
Safeguard software is
installed on an existing
system, users keep their
established Guardian default
security.
GUARDIAN DEFAULT
VOLUME
Sets the Guardian default
volume and subvolume for a
user.
The default value is
$SYSTEM.NOSUBVOL.
However, when the
Safeguard software is
installed on an existing
system, users keep their
established default volume
and subvolume.
CI-PROG Specifies the command
interpreter to be started
automatically after the user
logs on at a terminal controlled
by the Safeguard software.
The default value is no
command interpreter.
However, the CI-PROG
global configuration attribute
is set to
$SYSTEM.SYSTEM.TACL.
This value is used if no
command interpreter is
specified for the user or the
Safeguard terminal.
CI-LIB Specifies the library to be used
with the command interpreter
started after the user logs on
at a terminal controlled by the
Safeguard software.
The default value is no
library file.
CI-NAME Specifies the process name to
be given to the command
interpreter started after the
user logs on at a terminal
controlled by the Safeguard
software.
The default value is NONE.
The command interpreter is
be given a random name of
the form $Znnn.
CI-CPU Specifies the processor in
which the command
interpreter is to be started.
The default value is any
CPU.
Table 2-1. User Security Attributes and Default Attribute Values (page 4 of 5)
Attribute Description Default Value
1
The STATIC-FAILED-LOGON-RESET-TIME attribute is supported only on systems running H06.10 and later
H-series RVUs and G06.32 and later G-series RVUs.