Safeguard Administrator's Manual (G06.29+, H06.08+, J06.03+)
Controlling User Access
Safeguard Administrator’s Manual—523317-029
2-11
Adding Users to the System
Table 2-2 lists and describes the SAFECOM user security commands. The commands
are listed in the order in which they are normally used, rather than in alphabetic order.
CI-SWAP Specifies the swap volume to
be used when the command
interpreter is started after the
user logs on at a terminal
controlled by the Safeguard
software.
The default value is null.
CI-PRI Specifies the priority at which
the command interpreter is run
when it is started at a terminal
controlled by the Safeguard
software.
The default value is null.
However, the CI-PRI global
configuration attribute has a
value of 149. This value is
used if no priority is specified
for the user.
CI-PARAM-TEXT Specifies the parameter text to
be used when the command
interpreter is started after the
user logs on at a terminal
controlled by the Safeguard
software.
The default value is no text.
PRIMARY-GROUP Specifies the primary group for
the user.
The default value is the user
administrative group.
INITIAL-DIRECTORY Specifies the pathname for the
initial working directory for the
user in an OSS environment.
The default is no pathname.
INITIAL-PROGRAM Specifies the pathname for the
initial program for the user in
an OSS environment.
The default is no pathname.
INITIAL-PROGTYPE Specifies the initial program
type for the user in an OSS
environment.
The default is PROGRAM.
STATIC-FAILED-LOGON-
RESET
1
Specifies the last time when
the value of the attribute,
STATIC FAILED LOGON
COUNT, was reset.
The default is NONE.
Table 2-1. User Security Attributes and Default Attribute Values (page 5 of 5)
Attribute Description Default Value
1
The STATIC-FAILED-LOGON-RESET-TIME attribute is supported only on systems running H06.10 and later
H-series RVUs and G06.32 and later G-series RVUs.