Safeguard Administrator's Manual (G06.29+, H06.08+, J06.03+)
Controlling User Access
Safeguard Administrator’s Manual—523317-029
2-11
Adding Users to the System
Table 2-2 lists and describes the SAFECOM user security commands. The commands 
are listed in the order in which they are normally used, rather than in alphabetic order.
CI-SWAP Specifies the swap volume to 
be used when the command 
interpreter is started after the 
user logs on at a terminal 
controlled by the Safeguard 
software.
The default value is null.
CI-PRI Specifies the priority at which 
the command interpreter is run 
when it is started at a terminal 
controlled by the Safeguard 
software.
The default value is null. 
However, the CI-PRI global 
configuration attribute has a 
value of 149. This value is 
used if no priority is specified 
for the user. 
CI-PARAM-TEXT Specifies the parameter text to 
be used when the command 
interpreter is started after the 
user logs on at a terminal 
controlled by the Safeguard 
software.
The default value is no text. 
PRIMARY-GROUP Specifies the primary group for 
the user.
The default value is the user 
administrative group.
INITIAL-DIRECTORY Specifies the pathname for the 
initial working directory for the 
user in an OSS environment.
The default is no pathname.
INITIAL-PROGRAM Specifies the pathname for the 
initial program for the user in 
an OSS environment.
The default is no pathname.
INITIAL-PROGTYPE Specifies the initial program 
type for the user in an OSS 
environment.
The default is PROGRAM.
STATIC-FAILED-LOGON-
RESET 
1
Specifies the last time when 
the value of the attribute, 
STATIC FAILED LOGON 
COUNT, was reset.
The default is NONE.
Table 2-1. User Security Attributes and Default Attribute Values (page 5 of 5)
Attribute Description Default Value
1
 The STATIC-FAILED-LOGON-RESET-TIME attribute is supported only on systems running H06.10 and later 