Safeguard Management Programming Manual (G06.29+, H06.08+, J06.03+)

Commands
Safeguard Management Programming Manual422086-028
7-101
ALTER SUBSYSTEM Command
ZUNITS
specifies the unit of ZVALUE. This field must contain one of these values:
ZSFG-VAL-UNITS-SECONDS
ZSFG-VAL-UNITS-MINUTES
ZSFG-VAL-UNITS-HOURS
ZSFG-VAL-UNITS-DAYS
ZSFG-VAL-UNITS-WEEKS
ZSFG-VAL-UNITS-MONTHS
ZSFG-VAL-UNITS-YEARS
ZSFG-TKN-PSWD-HISTORY
is an optional token that specifies the number of previous passwords to retain in a
password database organized by user ID. Any new passwords must be different
from all the previous passwords. The default value is zero, indicating no password
history.
ZSFG-TKN-PSWD-MIN-LENGTH
is an optional token that specifies the minimum character length of a new
password. The default value is 0. The password can range between 0 to 64.
ZSFG-TKN-PSWD-MAY-CHANGE
is an optional token that specifies the number of days the user has to change his or
her password before it expires.
ZSFG-TKN-PSWD-REQUIRED
is an optional token that specifies whether a password is required for a super ID or
group manager to log on as another user. The default is FALSE.
ZSFG-TKN-PSWD-ENCRYPT
is an optional token that specifies whether new passwords are stored in an
encrypted form. The default is FALSE.
ZSFG-TKN-CHECK-DEVICE
is an optional token that specifies whether the device ACL is consulted to
determine access to devices and subdevices. The default is TRUE.
ZSFG-TKN-CHECK-SUBDEVICE
is an optional token that specifies whether the subdevice ACL is consulted to
determine access to subdevices. The default is FALSE.
Note. The default value is six only for systems running H06.06 and later H-series RVUs and
G06.29 and later G-series RVUs.
Note. The default is TRUE only for systems running H06.06 and later H-series RVUs and
G06.29 and later G-series RVUs.