Safeguard Management Programming Manual (G06.29+, H06.08+, J06.03+)
Error Numbers and Error Lists
Safeguard Management Programming Manual—422086-028
A-41
ZSFG-ERR-GROUP-ID-EXISTS
ZSFG-ERR-GROUP-ID-EXISTS
An attempt was made to perform ADD GROUP, but the group number already exists.
Tokens
ZSPI-TKN-ERROR
is the standard SPI error token, as described in the SPI Programming Manual. Its
value consists of the Safeguard subsystem ID and the error number ZSFG-ERR-
GROUP-ID-EXISTS. This token is always present in the error list.
ZCOM-TKN-OBJNAME
is the first object name provided with the command on which the error occurred.
This token is always present in the error list.
ZSFG-TKN-GROUPID
is the group ID of the group. This token is always present in the error list.
Probable Cause
An attempt was made to perform ADD GROUP, but the group number already exists.
Recommended Action
Specify a different group number.
ZSFG-ERR-GROUP-NAME-EXISTS
An attempt was made to perform ADD GROUP, but the group name already exists.
ZSPI-TKN-ERRLIST token type ZSPI-TYP-LIST
ZSPI-TKN-ERROR token type ZSPI-TYP-ERROR
ZCOM-TKN-OBJNAME token type ZSPI-TYP-STRING
ZSFG-TKN-GROUPID token type ZSPI-TYP-INT2
ZSPI-TKN-ENDLIST token type ZSPI-TYP-SSCTL
ZSPI-TKN-ERRLIST token type ZSPI-TYP-LIST
ZSPI-TKN-ERROR token type ZSPI-TYP-ERROR
ZCOM-TKN-OBJNAME token type ZSPI-TYP-STRING
ZSFG-TKN-GROUPNAME token type ZSPI-TYP-STRING
ZSPI-TKN-ENDLIST token type ZSPI-TYP-SSCTL