SCF Reference Manual for G-Series RVUs (G06.24+)
SCF Error Messages
SCF Reference Manual for G-Series RVUs—520413-004
B-8
SCF Error Messages
20001
Cause. You have exceeded the maximum number of times a command file can invoke
another command file. The limit is 10 times.
Effect. SCF closes the command file and waits for the next command.
Recovery. Find and correct the OBEY command that caused the recursive loop.
20002
Cause. The call to the system procedure USERDEFAULTS has failed.
Effect. SCF waits for the next command.
Recovery. Stop and restart SCF. If the problem persists, contact your service
provider, as described under If You Have to Call Your Service Provider on page B-2.
20003
Cause. The specified command can be used only while the input and output of SCF is
directed to your terminal.
Effect. SCF waits for the next command.
Recovery. Remove the command from your command file and reexecute the
command file.
20004
Cause. Too many comma-separated values have been specified in a list of numbers.
Effect. SCF waits for the next command.
Recovery. Remove the extra numbers from the command.
SCF 20001 Maximum number of nested OBEY files (n) exceeded.
SCF 20002 Can not obtain default volume and subvolume.
SCF 20003 This command is only valid in interactive mode.
SCF 20004 No more than n numbers are allowed in this list.