SCF Reference Manual for G-Series RVUs (G06.24+)
SCF Error Messages
SCF Reference Manual for G-Series RVUs—520413-004
B-31
SCF Error Messages
20300
Cause. SCF cannot find the ZsubsysSCF product module required to communicate
with the subsystem.
Effect. SCF waits for the next command.
Recovery. Install the ZsubsysSCF product module for the subsystem in the
$SYSTEM.SYSTEM subvolume or in the subvolume referenced by the PARAM
SCF^PM^LOC command.
20301
Cause. The ZsubsysSCF file is not an executable file. Either (1) the product module
file has been installed improperly or (2) the product module file has never been
installed and there exists a misnamed ZsubsysSCF file that SCF is trying to execute
as a subsystem product module.
Effect. SCF waits for the next command.
Recovery. Either (1) reinstall the ZsubsysSCF product module file or (2) rename the
misnamed file and install the correct ZsubsysSCF product module file.
20302
Cause. Error err-num has occurred while trying to start the ZsubsysSCF product
module. This error number is returned by the call to the PROCESS_CREATE_
procedure. One possible cause is having a home terminal name longer than 24
characters.
Effect. SCF waits for the next command.
Recovery. Refer to the Guardian Procedure Errors and Messages Manual for
recovery from the file-system error. Then retry the command.
SCF 20300 - SCF Product module, $volume.subvol.ZsubsysSCF,
not found.
SCF 20301 - SCF Product module, $volume.subvol.ZsubsysSCF,
not type 0 or 100.
SCF 20302 - SCF Product module, $volume.subvol.ZsubsysSCF,
not started, Guardian error: err-num.