20340
Cause. The TACL PARAM SCF^PM^LOC includes a system name specification.
Effect. SCF waits for the next command.
Recovery. Exit SCF and retry the TACL PARAM without the system name. Only
$volume.subvolume is accepted. Then restart SCF.
20342
Cause. Error err-num occurred when trying to do a PROCESS_GETINFOLIST_ on
the ZsubsysSCF product module.
Effect. SCF waits for the next command.
Recovery. Refer to Guardian Procedure Calls Reference Manual for recovery
information about the PROCESS_GETINFOLIST_ error.
20343
Cause. The SCF user library pmlibname being used by the ZsubsysSCF product
module is different from the scflibname library being used by SCF. This usually
happens when a product module refers to an SCF user library other than the SCFLIB
file on $SYSTEM.SYSTEM.
Effect. SCF waits for the next command.
Recovery. Perform the following procedure:
1. Exit SCF and run FUP to resecure the ZsubsysSCF product module file with write
access.
2. Enter a TACL PARAM SCF^LIB^MOVED, YES command.
3. Restart SCF and retry the command that led to the error.
4. Exit SCF and resecure the product module file.
5. Clear the TACL PARAM.
6. Retry the original command that produced this error.
SCF 20340 System name specified. Param SCF^PM^LOC ignored.
SCF 20342 SCF 20342 SCF Product module,
$volume.subvol.ZsubsysSCF, not started,
PROCESS_GETINFOLIST_ error, err-num
SCF 20343 SCF Product module, $volume.subvol.ZsubsysSCF,
stopped, due to library conflict. SCF library scflibname, PM
library pmlibname.