SCF Reference Manual for G-Series RVUs (G06.24+)
SCF Error Messages
SCF Reference Manual for G-Series RVUs—520413-004
B-42
SCF Error Messages
20344
Cause. A file-system error has occurred beyond the normal range for file-system
errors.
Effect. SCF waits for the next command.
Recovery. As described under If You Have to Call Your Service Provider on page B-2,
save pertinent information and contact your service provider.
20345
Cause. A LOCKSIZE value has been specified that is greater than the PAGES value.
If PAGES is not specified, LOCKSIZE must be less than or equal to 64 pages.
Effect. SCF waits for the next command.
Recovery. Retry the command with a LOCKSIZE value less than or equal to the
PAGES value.
20346
Cause. The parameter entered is not compatible with pre-D30 SCP. The LOCKSIZE,
BULKIO, and NOBULKIO options can be specified only with SCP versions D30 and
later.
Effect. SCF waits for the next command.
Recovery. Informational message only; no corrective action is needed.
20347
Cause. SCF or an SCF product module attempted to display more than 1024
characters. The data has been truncated.
Effect. SCF waits for the next command.
SCF 20344 PROCESS_CREATE_ error n on file-name.
SCF 20345 Trace command error. LOCKSIZE specified is greater
than PAGES.
SCF 20346 SCP version is less than D30. Trace parameter
param is ignored.
SCF 20347 Error message is longer than 1024 characters and
has been truncated.