SCF Reference Manual for G-Series RVUs (G06.24+)
SCF Error Messages
SCF Reference Manual for G-Series RVUs—520413-004
B-50
Common Error Messages
-00025
Cause. A command using the SUB modifier has been issued, but no subordinate
objects were found. This error is applicable only when the SUB modifier contains the
SUB-ONLY value, or the value of a specific object type.
Effect. SCF waits for the next command.
Recovery. Informational message only; no corrective action is needed.
-00026
Cause. An invalid, unknown, or unsupported token code has been encountered.
Effect. SCF terminates.
Recovery. As described under If You Have to Call Your Service Provider on page B-2,
save pertinent information and contact your service provider.
-00027
Cause. The command buffer contains more than one occurrence of a token that can
be specified only once.
Effect. SCF terminates.
Recovery. As described under If You Have to Call Your Service Provider
on page B-2,
save pertinent information and contact your service provider.
-00028
Cause. A token has been encountered whose length is either too large or too small.
Effect. SCF terminates.
Recovery. As described under If You Have to Call Your Service Provider on page B-2,
save pertinent information and contact your service provider.
subsystem {E|W}-00025 Object object-name has no subordinates.
subsystem {E|W}-00026 Internal Error: Invalid Token: Token
Code: hexadecimal-token-code (Tnm: token-number).
subsystem {E|W}-00027 Internal Error: Duplicate Token: Token
Code: hexadecimal-token-code (Tnm: token-number).
subsystem {E|W}-00028 Internal Error: Invalid Token Length:
Token Code: hexadecimal-token-code (Tnm: token-number, Len:
token-length).